+86-533-3571318

FRD Sensor FD80D Compact Industrial Pressure Transmitter for Space-Constrained Applications

Basic Properties
Place of Origin: China
Brand Name: FRD
Certification: IP65
Model Number: FD80D
Trading Properties
Minimum Order Quantity: one piece
Price: USD 30-200/piece
Payment Terms: L/C,D/A,D/P,T/T
Supply Ability: Production output can be flexibly adjusted according to order quantity.
Product Summary
1. IntroductionThe FRD Sensor FD80D Industrial Compact Pressure Transmitter is designed for industrial equipment and automation systems requiring reliable pressure measurement in limited installation spaces. With its compact structure and stable measurement performance, FD80D provides a practical ...

Product Details

Range: 0-100kPa ~ 7MPa (For Details, Please Refer To The Selection Table)
Pressure Type: Gauge Pressure
Overload Pressure: 1.5 Times Full-scale
Accuracy: 0.25% F.S.
Long-Term Stability: 0.2% F.S Per Year
Working Temperature: 0.2% F.S Per Year
Product Description

1. Introduction

The FRD Sensor FD80D Industrial Compact Pressure Transmitter is designed for industrial equipment and automation systems requiring reliable pressure measurement in limited installation spaces. With its compact structure and stable measurement performance, FD80D provides a practical solution for applications where installation flexibility, measurement reliability, and system compatibility are essential.

The FD80D is suitable for industrial automation, machinery, process monitoring, and pressure control applications. Its flexible output and communication options allow easy integration into different industrial control systems, helping users achieve reliable pressure monitoring and efficient system operation.


2. Why Choose This Model?

Industrial pressure measurement may face challenges such as limited installation space, unstable readings, measurement drift and difficult system integration.

FD80D addresses these needs with:

  • Compact Design: Suitable for equipment with limited installation space.
  • Stable Measurement: 0.25% F.S. accuracy with 0.2% F.S./year long-term stability.
  • Flexible Communication: Supports MODBUS RTU and HART protocols.
  • Wide Measurement Range: 0–100 kPa to 7 MPa.
  • Multiple Output Options: Supports 4–20 mA and 1–5 V DC.
  • Industrial Protection: IP65 protection for demanding industrial environments.

3. Model Comparison Table

ParameterFRD Sensor FD80DWIKA A-10H******l PX3 Series
Product TypeIndustrial Compact Pressure TransmitterPressure TransmitterHeavy-Duty Pressure Transducer
Measurement Range0–100 kPa to 7 MPaModel-dependentModel-dependent
Pressure TypeGauge PressureGauge / AbsoluteGauge / Absolute
Accuracy0.25% F.S.Up to ±0.25% F.S.Up to ±0.25% F.S.
Overload Pressure1.5 * F.S.Model-dependentModel-dependent
Long-Term Stability0.2% F.S./YearModel-dependentModel-dependent
Operating Temperature-20°C to 70°C-30°C to 100°C-40°C to 125°C
Power Supply18–30 VDC8–30 VDC8–30 VDC
Output Signal4–20 mA / 1–5 V DC4–20 mA / 0–10 V / 1–5 V, etc.4–20 mA / 0–5 V / 0–10 V, etc.
Communication ProtocolMODBUS RTU / HARTModel-dependentModel-dependent
Electrical ConnectorGDM / M12*1 Aviation PlugModel-dependentModel-dependent
Protection LevelIP65Up to IP67Up to IP67
Typical ApplicationsIndustrial Automation, Equipment Integration, Process MonitoringIndustrial Machinery & Process ApplicationsIndustrial, HVAC & Transportation
Warranty12 Months——

4. FRD Sensor FD80D OEM & ODM Customization Services

FRD Sensor provides flexible OEM & ODM customization services for FD80D to meet different equipment integration and pressure measurement requirements.

Customization options include:

  • Measurement range
  • Pressure type
  • Output signal
  • Communication protocol
  • Electrical connector
  • Mechanical configuration
  • OEM labeling

These options allow equipment manufacturers, automation companies and system integrators to efficiently integrate FD80D into different industrial applications.


5. FRD Sensor FD80D Industrial Compact Pressure Transmitter Measurement Accuracy Troubleshooting Guide

When FD80D shows abnormal pressure readings or measurement deviation, follow these steps:

Step 1: Check the Power Supply
Verify that the supply voltage is stable and within the specified 18–30 VDC range.

Step 2: Check the Pressure Connection
Inspect the pressure port and connection for leakage, blockage or improper installation.

Step 3: Check the Zero Point
Under the specified reference conditions, verify whether the transmitter has zero-point deviation.

Step 4: Check the Output Signal
Check whether the 4–20 mA or 1–5 V output corresponds correctly to the applied pressure.

Step 5: Check Communication & Configuration
Verify the MODBUS RTU or HART communication and confirm that the measurement range and configuration parameters are correct.

If the problem persists, contact FRD Sensor for technical support.

6. Product Certifications

FRD Sensor FD80D Compact Industrial Pressure Transmitter for Space-Constrained Applications


7.Conclusion

The FRD Sensor FD80D Industrial Compact Pressure Transmitter combines a compact design, stable measurement performance, and flexible signal configurations to meet diverse industrial pressure measurement requirements. It is a practical choice for equipment manufacturers and system integrators seeking reliable pressure monitoring in space-constrained installations.

FRD Sensor also provides OEM and ODM customization services, allowing measurement ranges, output signals, communication protocols, and installation connections to be configured according to specific application requirements. This enables customers to achieve a pressure measurement solution that better matches their equipment design and system integration needs.

Related Products