Data Center Liquid Cooling Solutions: FRD Sensor Pressure & Differential Pressure Transmitters for CDU Systems

2026-11-14

Latest company case about Data Center Liquid Cooling Solutions: FRD Sensor Pressure & Differential Pressure Transmitters for CDU Systems
Case Detail

As demand for AI computing, high-performance computing (HPC), and data center infrastructure continues to grow, traditional air cooling is facing increasing challenges in heat dissipation efficiency, energy consumption, and space utilization. Liquid cooling technology, with its higher heat transfer efficiency and more effective thermal management capabilities, is becoming an important solution for next-generation data centers.

In liquid cooling systems, the Coolant Distribution Unit (CDU) plays a critical role in coolant circulation, heat exchange, and fluid distribution. Pressure and differential pressure measurements are essential for monitoring coolant circuit conditions, supporting pump control, identifying filter resistance changes, and maintaining stable system operation.

FRD Sensor focuses on CDU water-cooling and water-glycol cooling circuits, providing compact pressure transmitters, micro differential pressure transmitters, and digital pressure measurement solutions for liquid cooling equipment manufacturers. These solutions help monitor coolant pressure, identify fluid resistance changes, and improve system operating condition monitoring.

01. Industry Challenges: Key Measurement Requirements in CDU Liquid Cooling Systems

Liquid cooling equipment typically features compact internal spaces, complex piping connections, and continuous operating conditions. These characteristics place higher demands on pressure and differential pressure measurement components.

1. Sealing Reliability and Leakage Prevention

CDU systems contain numerous coolant pipelines, fittings, and measurement components. Leakage from sensor connections or sealing structures may cause equipment downtime and potentially affect the operation of servers and other critical equipment.

2. Space-Constrained Installation

CDU cabinets and fluid distribution manifolds have limited internal space. Conventional large-sized transmitters may be difficult to integrate, creating demand for compact sensor dimensions, flexible installation interfaces, and adaptable connection configurations.

3. Coolant Media Compatibility

Different liquid cooling projects may use different coolant formulations, including water and water-glycol mixtures. Sensor wetted materials and sealing elements must be evaluated for compatibility with the coolant composition, concentration, and operating temperature.

4. Micro Differential Pressure Measurement and Temperature Drift

Pressure drop variations across heat exchangers, filters, and circulation pipelines are commonly monitored through differential pressure measurement. Low differential pressure applications require good zero-point stability, effective temperature compensation, and consistent long-term measurement performance.

latest company case about Data Center Liquid Cooling Solutions: FRD Sensor Pressure & Differential Pressure Transmitters for CDU Systems

02. FRD Sensor Solutions: From Sensor Technology to System Integration

Supported by proprietary monocrystalline silicon sensing technology, digital compensation technology, and automated manufacturing capabilities, FRD Sensor provides configurable pressure and differential pressure measurement solutions for CDU liquid cooling applications.

01 Compact Structural Design

Designed for space-constrained CDU cabinets and fluid distribution manifolds, FRD Sensor offers compact sensor structures with various threaded and quick-connect interface options to facilitate equipment integration and installation.

02 Sealing Design and Leakage Verification

Through optimized sealing structures, welding processes, and sealing performance verification, FRD Sensor aims to improve product reliability in liquid cooling circuits. For projects with specific requirements, helium mass spectrometer leak testing can be evaluated according to customer specifications.

03 Coolant Media Compatibility Evaluation

Based on coolant type, glycol concentration, operating temperature, and pressure conditions, FRD Sensor evaluates the compatibility of wetted materials and sealing elements and provides corresponding material and structural customization options.

04 High-Stability Differential Pressure Measurement

Monocrystalline silicon sensing technology combined with digital temperature compensation helps improve zero-point stability and environmental adaptability in low differential pressure applications. This supports pressure drop monitoring across filters, heat exchangers, and fluid circuits.

03. Product Selection: Matching Different CDU Measurement Points

Different measurement locations require different pressure types, measurement ranges, output signals, and installation interfaces. FRD Sensor can provide corresponding product configurations based on specific operating conditions.

Application Location

Key Measurement Requirement

Recommended Solution

CDU heat exchanger inlet and outlet

Monitor differential pressure and resistance variations across the heat exchanger

Compact Differential Pressure Transmitter

Filter inlet and outlet

Monitor filter pressure drop and potential clogging trends

Micro Differential Pressure Transmitter

Secondary-side supply and return pipelines

Monitor pipeline pressure and system operating conditions

Miniature Pressure Transmitter

Coolant circulation pump discharge

Dynamic pressure monitoring and pump operating condition feedback

Digital Pressure Transmitter

04. Engineering Selection Guide: How to Select Pressure and Differential Pressure Transmitters for Liquid Cooling Systems

Q1: Where should pressure and differential pressure transmitters be installed in a CDU system?

Common measurement points include secondary-side coolant supply and return pipelines, circulation pump discharge ports, heat exchanger inlets and outlets, and filter inlets and outlets.

Pressure transmitters are primarily used to monitor supply and return pipeline pressure and pump discharge pressure. Differential pressure transmitters are used to monitor pressure losses across heat exchangers, filters, and other fluid circuits, providing measurement data for operating condition assessment and hydraulic balancing.

Q2: How should wetted materials be selected for liquid cooling applications?

Wetted materials should not be selected based solely on the general term "liquid cooling." The specific coolant composition, glycol concentration, operating temperature, and long-term operating conditions must first be confirmed. The compatibility of metallic wetted components and sealing materials should then be evaluated.

FRD Sensor can assess suitable material and sealing configurations based on the customer's coolant specifications and operating conditions.

Q3: Why is micro differential pressure monitoring important in CDU systems?

Micro differential pressure monitoring helps identify resistance changes across filters, heat exchangers, and fluid pipelines.

For example, as contaminants accumulate in a filter, the pressure difference between its inlet and outlet may change. Variations in internal flow resistance across a heat exchanger can also be identified through differential pressure measurements.

These measurements provide useful reference data for maintenance decisions, pump speed adjustment, and system operation optimization.

Q4: What information should CDU equipment manufacturers provide when selecting pressure transmitters?

To improve product selection and customization efficiency, the following information is recommended:

  • Coolant type and glycol concentration

  • Measurement type: gauge pressure or differential pressure

  • Pressure and differential pressure measuring ranges

  • Coolant operating temperature

  • Maximum operating pressure and potential pressure fluctuations

  • Available installation space and interface dimensions

  • Output signals and communication protocols

  • Wetted material and sealing requirements

  • Estimated annual purchase volume and project delivery requirements

05. OEM & ODM Cooperation: From Structural Adaptation to Mass Production

FRD Sensor provides professional OEM and ODM customization services for global CDU equipment manufacturers, liquid cooling system integrators, and industrial automation partners.

STEP 1: Operating Conditions and Coolant Verification

Confirm coolant type, measurement range, operating temperature, pressure conditions, and system requirements.

STEP 2: Structural and Interface Adaptation

Evaluate transmitter dimensions, installation methods, and connection interfaces according to CDU internal space and piping layouts. Customized structural designs are available based on project requirements.

STEP 3: Sealing and Environmental Validation

Conduct sealing performance, temperature cycling, and relevant reliability evaluations according to project specifications. Helium mass spectrometer leak testing can also be evaluated when required.

STEP 4: Sample Testing and Volume Delivery

After sample evaluation, parameter confirmation, and product validation, FRD Sensor proceeds with mass production and delivery, providing ongoing technical support to customers.

latest company case about Data Center Liquid Cooling Solutions: FRD Sensor Pressure & Differential Pressure Transmitters for CDU Systems

06. Recommended FRD Sensor Product Portfolio for Liquid Cooling Applications
  • CDU Compact Differential Pressure Transmitter: Designed for differential pressure monitoring across heat exchangers, filters, and fluid circuits.

  • Miniature Industrial Pressure Transmitter: Suitable for coolant supply pipelines, return pipelines, and circulation pump discharge pressure monitoring.

  • Modbus Digital Pressure Sensor: Designed for liquid cooling equipment requiring digital signal transmission and system integration.

07. Partner with FRD Sensor for Reliable Liquid Cooling Measurement Solutions

As AI computing infrastructure and data center liquid cooling technologies continue to evolve, pressure and differential pressure measurement components are becoming increasingly important in CDU fluid control systems.

FRD Sensor will continue to focus on industrial pressure and differential pressure measurement technology, addressing the requirements of liquid cooling systems for compact structures, sealing reliability, media compatibility, and long-term measurement stability.

We provide flexible product configurations and OEM & ODM customization services for global liquid cooling equipment manufacturers.

Developing a CDU liquid cooling system? Contact FRD Sensor to discuss your measurement requirements.

  • Submit your liquid cooling system parameters for product selection recommendations.

  • Request product dimensions and 3D CAD interface models.

  • Discuss OEM & ODM customization and sample evaluation solutions.

FRD Sensor — Reliable Pressure & Differential Pressure Measurement for Data Center Liquid Cooling.