Welcome to Shandong Friend Control System Co., Ltd.
+86-533-3571318

FD80D Industrial Compact Pressure Transmitter with 0.25% F.S. Accuracy, MODBUS RTU and HART Protocols, and IP65 Protection

Product Summary
1. Introduction The FRD Sensor FD80D Industrial Compact Pressure Transmitter is designed for industrial pressure measurement where installation space, measurement stability, and system integration are important considerations. Its compact structure makes it suitable for equipment with limited ...

Product Details

Highlight:

0.25% F.S. Accuracy Pressure Transmitter

,

MODBUS RTU and HART Protocols Compact Pressure Transmitter

,

IP65 Protection Industrial Pressure Transmitter

Product Description

1. Introduction

The FRD Sensor FD80D Industrial Compact Pressure Transmitter is designed for industrial pressure measurement where installation space, measurement stability, and system integration are important considerations. Its compact structure makes it suitable for equipment with limited mounting space, while its flexible signal and communication options support different industrial control systems.

The FD80D can be applied to equipment monitoring, process control, industrial automation, and other pressure measurement applications. It provides a practical solution for customers who need a compact transmitter with stable performance and flexible integration.


2. Why Choose This Model?

Industrial pressure measurement may face challenges such as limited installation space, unstable readings, measurement drift and difficult system integration.

FD80D addresses these needs with:

  • Compact Design: Suitable for equipment with limited installation space.
  • Stable Measurement: 0.25% F.S. accuracy with 0.2% F.S./year long-term stability.
  • Flexible Communication: Supports MODBUS RTU and HART protocols.
  • Wide Measurement Range: 0–100 kPa to 7 MPa.
  • Multiple Output Options: Supports 4–20 mA and 1–5 V DC.
  • Industrial Protection: IP65 protection for demanding industrial environments.

3. Model Comparison Table

Parameter FRD Sensor FD80D WIKA A-10 H******l PX3 Series
Product Type Industrial Compact Pressure Transmitter Pressure Transmitter Heavy-Duty Pressure Transducer
Measurement Range 0–100 kPa to 7 MPa Model-dependent Model-dependent
Pressure Type Gauge Pressure Gauge / Absolute Gauge / Absolute
Accuracy 0.25% F.S. Up to ±0.25% F.S. Up to ±0.25% F.S.
Overload Pressure 1.5 * F.S. Model-dependent Model-dependent
Long-Term Stability 0.2% F.S./Year Model-dependent Model-dependent
Operating Temperature -20°C to 70°C -30°C to 100°C -40°C to 125°C
Power Supply 18–30 VDC 8–30 VDC 8–30 VDC
Output Signal 4–20 mA / 1–5 V DC 4–20 mA / 0–10 V / 1–5 V, etc. 4–20 mA / 0–5 V / 0–10 V, etc.
Communication Protocol MODBUS RTU / HART Model-dependent Model-dependent
Electrical Connector GDM / M12*1 Aviation Plug Model-dependent Model-dependent
Protection Level IP65 Up to IP67 Up to IP67
Typical Applications Industrial Automation, Equipment Integration, Process Monitoring Industrial Machinery & Process Applications Industrial, HVAC & Transportation
Warranty 12 Months — —

4. FRD Sensor FD80D OEM & ODM Customization Services

FRD Sensor provides flexible OEM & ODM customization services for FD80D to meet different equipment integration and pressure measurement requirements.

Customization options include:

  • Measurement range
  • Pressure type
  • Output signal
  • Communication protocol
  • Electrical connector
  • Mechanical configuration
  • OEM labeling

These options allow equipment manufacturers, automation companies and system integrators to efficiently integrate FD80D into different industrial applications.


5. FRD Sensor FD80D Industrial Compact Pressure Transmitter Measurement Accuracy Troubleshooting Guide

When FD80D shows abnormal pressure readings or measurement deviation, follow these steps:

Step 1: Check the Power Supply
Verify that the supply voltage is stable and within the specified 18–30 VDC range.

Step 2: Check the Pressure Connection
Inspect the pressure port and connection for leakage, blockage or improper installation.

Step 3: Check the Zero Point
Under the specified reference conditions, verify whether the transmitter has zero-point deviation.

Step 4: Check the Output Signal
Check whether the 4–20 mA or 1–5 V output corresponds correctly to the applied pressure.

Step 5: Check Communication & Configuration
Verify the MODBUS RTU or HART communication and confirm that the measurement range and configuration parameters are correct.

If the problem persists, contact FRD Sensor for technical support.

6. Product Certifications

FD80D Industrial Compact Pressure Transmitter with 0.25% F.S. Accuracy, MODBUS RTU and HART Protocols, and IP65 Protection


7.Conclusion

The FRD Sensor FD80D Industrial Compact Pressure Transmitter provides a practical solution for industrial applications where space is limited and reliable pressure measurement is required. Its compact design, flexible integration options, and customizable configuration make it suitable for different equipment and system requirements.

For OEM and ODM projects, FRD Sensor can also adjust the transmitter configuration according to specific application and integration needs, helping customers achieve a more suitable pressure measurement solution.

Related Products

Send An Inquiry