Welcome to Shandong Friend Control System Co., Ltd.
+86-533-3571318

FRD Sensor FD820C Embedded Micro Differential Pressure Transmitter for Cleanroom and HVAC Applications

Basic Properties
Place of Origin: China
Brand Name: FRD
Certification: Ex ia IIB T6 Ga
Model Number: FD820C
Trading Properties
Minimum Order Quantity: one piece
Price: USD 30-200/piece
Payment Terms: L/C,D/A,D/P,T/T
Supply Ability: Production output can be flexibly adjusted according to order quantity.
Product Summary
1. Introduction The FRD Sensor FD820C Embedded Micro Differential Pressure Transmitter is designed for low-range differential pressure measurement in cleanrooms, HVAC systems, laboratories, medical facilities, and industrial air-handling applications. With a compact embedded design, the FD820C ...
Product Description

1. Introduction

The FRD Sensor FD820C Embedded Micro Differential Pressure Transmitter is designed for low-range differential pressure measurement in cleanrooms, HVAC systems, laboratories, medical facilities, and industrial air-handling applications.

With a compact embedded design, the FD820C provides stable differential pressure monitoring for applications where space is limited and reliable pressure feedback is essential. It can be integrated with PLC, HVAC control systems, DCS, and other automation platforms.

Typical applications include cleanroom pressure monitoring, FFU systems, air filter differential pressure detection, ventilation control, and isolation room pressure monitoring.

2. Why Choose This Model?

Micro differential pressure applications often face challenges such as limited installation space, unstable measurement, long-term accuracy drift and difficult system integration.

FD820C addresses these challenges with:

  • Compact embedded design for space-constrained and OEM equipment.
  • Stable measurement performance with accuracy up to ±0.5% F.S. and long-term stability of 0.2% F.S./Year.
  • Flexible communication with 4–20 mA, RS485, Relay and MODBUS RTU.
  • Wide measurement range from 0–100 Pa to 2500 Pa.
  • Explosion-proof option: Ex ia IIB T6 Ga.
  • FRD Sensor FD820C Embedded Micro Differential Pressure Transmitter for Cleanroom and HVAC Applications
3. Model Comparison Table
Parameter FRD Sensor FD820C Ho*******l DPTE1000 Si****s QBM3120-25
Product Type Embedded Micro Differential Pressure Transmitter Differential Pressure Transmitter Differential Pressure Sensor
Pressure Range 0–100 Pa to 2500 Pa 0–1000 / 2500 Pa 0–2500 Pa
Accuracy ±0.5% F.S.; ±1.0% F.S. optional ≤ ±1.0% F.S.
Operating Temperature 0°C to 60°C 0°C to 50°C
Power Supply 16–32 VDC 18–30 V AC/DC 24 V AC/DC
Output Signal 4–20 mA / RS485 + Relay 0–10 V / 4–20 mA 4–20 mA
Communication Protocol MODBUS RTU Analog Output Analog Output
Explosion Protection Ex ia IIB T6 Ga
Construction Compact Embedded Design Compact Transmitter Design Compact Sensor Design
Typical Applications Cleanrooms, HVAC, Medical Equipment, Laboratories, Electronics Manufacturing, Industrial Ventilation HVAC, Ventilation, Building Automation HVAC, Ventilation, Air Handling
Parameter FD820C
Range 0-100Pa~2500Pa
Pressure Type Differential Pressure
Overload Capacity Allows overload pressure 2 times and destroys pressure 4 times the sensor range
Accuracy 0.5%F.S; 1.0%F.S(optional)
Long Term Stability 0.2%F.S/Year
Operating Temperature 0℃~60℃
Power Supply 16V~32VDC
Output Signal 4mA~20mA DC,RS485+Relay
Protocol MODBUS RTU
Explosion-Proof Ex ia IIB T6 Ga
Ambient Temperature Stainless Steel
Warranty Period 12 months
4. FRD Sensor FD820C OEM & ODM Customization Services

FRD Sensor provides flexible OEM & ODM customization services for FD820C based on different equipment and application requirements.

Key customization options include:

  • Measurement range
  • Output signal
  • Communication protocol
  • Mechanical configuration
  • OEM labeling and equipment integration

These services help OEM manufacturers and system integrators integrate FD820C into micro differential pressure monitoring equipment efficiently.

FRD Sensor FD820C Embedded Micro Differential Pressure Transmitter for Cleanroom and HVAC Applications

5. FRD Sensor FD820C Micro Differential Pressure Transmitter Measurement Accuracy Troubleshooting Guide

When FD820C measurement accuracy is abnormal, follow these steps:

  1. Step 1: Check Power Supply & Wiring
    Verify the 16–32 VDC power supply, wiring and output signal.
  2. Step 2: Check Pressure Connections
    Check the high- and low-pressure connections for leakage, blockage or incorrect installation.
  3. Step 3: Check Zero Point
    Confirm that the transmitter has been correctly zeroed under the specified reference condition.
  4. Step 4: Check Communication Settings
    Verify the MODBUS RTU address, baud rate and communication parameters.
  5. Step 5: Check Operating Conditions
    Confirm that pressure and temperature are within the specified operating range.

If the issue persists, contact FRD Sensor for technical support.

6. Application Scenarios

FRD Sensor FD820C Embedded Micro Differential Pressure Transmitter for Cleanroom and HVAC ApplicationsFRD Sensor FD820C Embedded Micro Differential Pressure Transmitter for Cleanroom and HVAC Applications

7. Product Certifications

FRD Sensor FD820C Embedded Micro Differential Pressure Transmitter for Cleanroom and HVAC Applications

8. Packing

FRD Sensor FD820C Embedded Micro Differential Pressure Transmitter for Cleanroom and HVAC Applications

9.Conclusion

The FRD Sensor FD820C Embedded Micro Differential Pressure Transmitter provides a compact solution for low differential pressure monitoring in cleanrooms, HVAC systems, laboratories, FFU units, and ventilation applications.

With flexible output options, compact installation, and OEM & ODM customization capabilities, the FD820C can be integrated into a wide range of pressure monitoring and control systems.