Welcome to Shandong Friend Control System Co., Ltd.
+86-533-3571318

FD80F Sanitary Flush Diaphragm Pressure Transmitter: Reliable Pressure Measurement for Hygienic Processes

Basic Properties
Place of Origin: China
Brand Name: FRD
Certification: IP65/IP68
Model Number: FD80F
Trading Properties
Minimum Order Quantity: one piece
Price: USD 30-200/piece
Payment Terms: L/C,D/A,D/P,T/T
Supply Ability: Production output can be flexibly adjusted according to order quantity.
Product Summary
1. Introduction The FRD Sensor FD80F Sanitary Flush Diaphragm Pressure Transmitter is designed for hygienic process applications in food, beverage, pharmaceutical, dairy and biotechnology industries. With a flush diaphragm design, digital temperature compensation and nonlinear correction, FD80F ...

Product Details

Range: -0.1MPa ~ 40MPa
Accuracy: 0.5% F.S
Output Signal: 4-20mA
Response Time: ≤500ms
Power Supply: 24VDC
Wetted Material: 316L, Tantalum Diaphragm, Ceramic Diaphragm
Housing Material: Stainless Steel
Long-Term Stability: 0.1% F.S Per Year
Process Connection: Clamp DN15/DN25/DN40, Thread M27×2, Flange
Warranty Period: 12 Months
Product Description
1. Introduction

The FRD Sensor FD80F Sanitary Flush Diaphragm Pressure Transmitter is designed for hygienic process applications in food, beverage, pharmaceutical, dairy and biotechnology industries.

With a flush diaphragm design, digital temperature compensation and nonlinear correction, FD80F helps minimize media residue and dead spaces while supporting high-temperature configurations for demanding hygienic processes.

2. Why Choose This Model?

Hygienic pressure measurement often faces challenges such as media residue, difficult cleaning, bacterial growth, temperature effects and clogging of conventional pressure connections.

FD80F addresses these challenges with:

  • Flush diaphragm design to minimize dead spaces and media residue.
  • 3-A hygienic design for food, beverage and pharmaceutical applications.
  • Stable measurement with digital temperature compensation and nonlinear correction.
  • High-temperature option with process temperatures up to 180°C.
  • Flexible outputs including 4–20 mA, HART and RS485.
  • High protection options up to IP65/IP68.
3. Model Comparison Table
Parameter FRD Sensor FD80F WIKA SA-11 ifm PM11
Product Type Sanitary Flush Diaphragm Pressure Transmitter Sanitary Pressure Transmitter Sanitary Flush-Mount Pressure Transmitter
Pressure Range -0.1 MPa to 40 MPa 0–25 kPa to 2.5 MPa -0.1 MPa to approx. 2.5 MPa*
Accuracy 0.5% F.S. ≤0.5% of span
Output Signal 4–20 mA 4–20 mA / 0–20 mA / 0–10 V 4–20 mA / IO-Link
Response Time ≤500 ms
Power Supply 24 VDC 10/14–30 VDC
Wetted Material 316L / Tantalum Diaphragm / Ceramic Diaphragm 1.4435 Stainless Steel Diaphragm
Housing Material Stainless Steel Stainless Steel
Long-Term Stability 0.1% F.S./Year ≤0.2% of span/year
Process Connection Clamp DN15/DN25/DN40, M27*2 Thread, Flange Clamp, Threaded, VARINLINE®, NEUMO® Integrated 1.5" Tri-Clamp
Protection Rating Up to IP68
Process Temperature Up to 150°C Up to 150°C
Typical Applications Food, Beverage, Pharmaceutical, Dairy, Biotechnology Food, Beverage, Pharmaceutical, Biotechnology Food & Beverage, Hygienic Processes
Warranty 12 Months
4. FRD Sensor FD80F OEM & ODM Customization Services

FRD Sensor provides flexible OEM & ODM customization services for FD80F based on hygienic process and equipment requirements.

Key customization options include:

  • Measurement range
  • Pressure type
  • Process connection
  • Output signal
  • Communication protocol
  • High-temperature configuration
  • Display and mechanical configuration

These services help food, pharmaceutical and biotechnology equipment manufacturers integrate FD80F into pressure measurement systems efficiently.

5. FRD Sensor FD80F Sanitary Flush Diaphragm Pressure Transmitter Measurement Accuracy Troubleshooting Guide

When FD80F shows abnormal pressure readings, follow these steps:

Step 1: Check the Hygienic Process Connection
Verify that the Tri-Clamp or other process connection is correctly installed and check for leakage.

Step 2: Check the Diaphragm
Inspect the flush diaphragm for media residue, deposits or mechanical damage.

Step 3: Check the Zero Point
Verify the transmitter zero point under the specified reference condition and perform zero calibration if necessary.

Step 4: Check Temperature Conditions
Confirm that the process and ambient temperatures are within the specified operating range.

Step 5: Check Output & Communication
Verify the 4–20 mA, HART or RS485 signal and related communication parameters.

If the issue persists, contact FRD Sensor for technical support.

6. Product Certifications
FD80F Sanitary Flush Diaphragm Pressure Transmitter: Reliable Pressure Measurement for Hygienic Processes
7.Conclusion

The FRD Sensor FD80F Sanitary Flush Diaphragm Pressure Transmitter is designed for hygienic pressure measurement in food, beverage, pharmaceutical and biotechnology applications. With its flush diaphragm, 3-A hygienic design, digital compensation and high-temperature options, FD80F helps reduce media residue and cleaning challenges while providing stable and reliable pressure measurement for hygienic processes.

Related Products

Send An Inquiry