Welcome to Shandong Friend Control System Co., Ltd.
+86-533-3571318

High Temp, High Viscosity & Scale Build-up, Large Blind Spots? Shandong FRD Sensor FD3051 LD Remote Flange Level Transmitter Solves Level Measurement Pain Points

Basic Properties
Place of Origin: China
Brand Name: FRD
Certification: SIL, IP66
Model Number: FD3051LD
Trading Properties
Minimum Order Quantity: 1piece
Price: USD 30-200/piece
Payment Terms: L/C,D/A,D/P,T/T,Western Union
Supply Ability: Production output can be flexibly adjusted according to order quantity.
Product Summary
1. Introduction The Shandong FRD Sensor FD3051 LD remote flange level transmitter is an industrial-grade level measuring instrument designed for high-temperature, high-viscosity, easy-to-crystallize, or highly corrosive media, widely used for vessel level and interface monitoring in industries such ...

Product Details

Range: 0-0.5m ~ 10mH₂O (see The Selection Table For Details)
Accuracy: 0.25%FS, 0.5%FS
Power Supply: (12~32)VDC (24VDC Recommended)
Long-Term Stability: 0.1% F.S / Year
Electronic Connection: M20*1.5(F), Special Customization Available
Explosion-Proof Grade: Exia 1l CT6 Ga,Exd Ll CT6 Gb,ExtD A21 IP66 T80℃
Product Description
1. Introduction

The Shandong FRD Sensor FD3051 LD remote flange level transmitter is an industrial-grade level measuring instrument designed for high-temperature, high-viscosity, easy-to-crystallize, or highly corrosive media, widely used for vessel level and interface monitoring in industries such as petrochemicals, pharmaceuticals, and food engineering.

High Temp, High Viscosity & Scale Build-up, Large Blind Spots? Shandong FRD Sensor FD3051 LD Remote Flange Level Transmitter Solves Level Measurement Pain Points

2. Why Choose This Model?
  • Addressing customer pain points such as scale build-up and clogging at impulse ports when measuring high-temperature and high-viscosity media, measurement lag caused by capillary transmission affected by temperatures, and leaks caused by corrosive liquids, the FD3051 LD features a large flush flange, a high-performance capillary fill fluid system, and corrosion-resistant diaphragm isolation technology to effectively prevent media precipitation and clogging, ensuring real-time and precise level data in harsh working conditions.
3. Model Comparison Table

FD3051LD FD3051LT
Range 0-0.5m ~ 10mH₂O (see the selection table for details) 0 - 0.5m ~ 50mH2O
Accuracy 0.25%FS, 0.5%FS 0.25%FS, 0.5%FS
Output Signal 4~20mA with HART, 1V ~ 5V DC, RS485 protocol 4~20mA with HART, RS485 protocol
Power Supply (12~32)VDC (24VDC recommended) (12~32)VDC (24VDC recommended)
Long-term Stability 0.1% F.S / year 0.1% F.S / year
Electronic Connection M20*1.5(F), special customization available M20*1.5(F)
Explosion-proof Grade Exia 1l CT6 Ga,Exd ll CT6 Gb,ExtD A21 IP66 T80℃ Exia 1l CT6 Ga,Exd ll CT6 Gb,ExtD A21 IP66 T80℃
4. FRD Sensor FD3051LD OEM & ODM Customization Services

Shandong FRD provides global clients with flexible OEM and ODM customization services, covering various flange sizes (ANSI, JIS, DIN standards), customized capillary lengths, extended thermowell depths, and corrosion-resistant material customization meeting specific industry certifications.

5. FRD Sensor FD3051LD Differential Pressure Transmitter Measurement Accuracy Troubleshooting Guide

If level reading deviations or sluggish responses occur, troubleshoot as follows: 1. Check if the remote flange diaphragm surface has scale, attachments, or mechanical damage; 2. Confirm whether the capillary tube is squeezed, bent, or subject to abnormal local temperature changes; 3. Check the positive and negative impulse systems and sealing to eliminate leaks; 4. Calibrate the transmitter zero and span, and recalibrate via a communicator if necessary.

6. Application Scenarios
High Temp, High Viscosity & Scale Build-up, Large Blind Spots? Shandong FRD Sensor FD3051 LD Remote Flange Level Transmitter Solves Level Measurement Pain Points
7. Product Drawing
High Temp, High Viscosity & Scale Build-up, Large Blind Spots? Shandong FRD Sensor FD3051 LD Remote Flange Level Transmitter Solves Level Measurement Pain Points High Temp, High Viscosity & Scale Build-up, Large Blind Spots? Shandong FRD Sensor FD3051 LD Remote Flange Level Transmitter Solves Level Measurement Pain Points
8. Product Certifications
High Temp, High Viscosity & Scale Build-up, Large Blind Spots? Shandong FRD Sensor FD3051 LD Remote Flange Level Transmitter Solves Level Measurement Pain Points
9. Conclusion

With its anti-scaling flush structure, high-precision capillary transmission, and exceptional high-temperature and corrosion resistance, the Shandong FRD Sensor FD3051 LD remote flange level transmitter thoroughly resolves level measurement pain points in complex industrial vessels, making it the ideal level monitoring solution for demanding environments.

Related Products

Send An Inquiry