1. Product Introduction
In cleanrooms, HVAC systems, laboratories, medical environments, semiconductor manufacturing, and smart building applications, stable micro differential pressure monitoring plays a critical role in airflow control, environmental safety, and equipment operation efficiency.
The FRD Sensor FD820CG Smart Micro Differential Pressure Transmitter is designed for low differential pressure and high-sensitivity measurement applications, enabling real-time monitoring of small pressure variations between rooms, equipment, or controlled environments.
In practical applications, clean environments usually involve very small pressure differences. Factors such as temperature changes, airflow disturbance, equipment start-up, and environmental fluctuations may cause measurement deviation, signal instability, and unreliable monitoring results.
The FD820CG integrates high-precision micro differential pressure sensing technology, intelligent temperature compensation algorithms, and reliable signal processing technology to improve measurement accuracy and long-term stability. With enhanced monitoring capabilities, it provides a more intuitive and efficient micro differential pressure measurement solution for clean environments, HVAC systems, and automation control applications.

2. Why Choose This Model?
In cleanrooms, HVAC systems, and precision environmental control applications, users require not only accurate micro differential pressure measurement but also convenient monitoring, stable operation, and efficient equipment management.
To address common field challenges, the FRD Sensor FD820CG Smart Micro Differential Pressure Transmitter provides a reliable solution for micro differential pressure monitoring.
1) Solve the Challenge of Measuring Small Pressure Variations
In cleanrooms and laboratories, differential pressure levels are usually very low. Conventional pressure instruments may have insufficient sensitivity or slow response, making it difficult to accurately detect environmental changes.
The FRD Sensor FD820CG adopts high-sensitivity micro differential pressure sensing technology to accurately capture small pressure variations and provide reliable data support for environmental control systems.
2) Reduce Measurement Errors Caused by Temperature Changes
Temperature fluctuations may affect sensor performance, causing zero-point changes and measurement deviations during long-term operation.
The FD820CG adopts intelligent temperature compensation technology to reduce the influence of temperature variations and maintain stable measurement output under different environmental conditions.
3) Improve On-Site Monitoring Efficiency with Intuitive Data Display
Traditional micro differential pressure instruments often require connection to external control systems for data viewing, making real-time field monitoring inconvenient.
The FD820CG provides a more intuitive monitoring method, allowing operators to quickly understand pressure conditions and improve equipment management efficiency.
4) Improve Pressure Control Stability in Clean Environments
Cleanrooms and isolation areas require stable pressure gradients to maintain proper airflow direction and prevent environmental contamination.
The FD820CG provides reliable data acquisition and stable signal output, helping control systems adjust airflow and pressure conditions more effectively.
5) Solve Installation Space Limitations and Improve System Integration
Traditional pressure instruments may have larger dimensions, creating challenges when installed inside air handling units, equipment panels, or compact control spaces.
The FD820CG features a compact structural design, enabling flexible installation and improving system integration efficiency for various applications.
6) Support Intelligent System Management and Automation Integration
Modern HVAC and clean environment systems require real-time data collection and integration with automation platforms.
The FD820CG supports industrial standard signal outputs and can be easily integrated with:
- PLC control systems
- BMS building management systems
- Environmental monitoring platforms
Enabling pressure data acquisition, remote monitoring, and intelligent system management.
7) Reduce Maintenance Requirements and Improve Long-Term Reliability
Unstable micro differential pressure monitoring equipment may require frequent calibration and maintenance, increasing operational costs.
The FD820CG adopts high-stability sensing components and reliable manufacturing processes to improve long-term performance, reduce maintenance frequency, and enhance system reliability.

3. Model Comparison Table
| Parameter |
FD820C |
FD820CG |
| Range |
0-100Pa~2500Pa |
Differential:0-50Pa~2500Pa,Humidity:0%~100%RH,Temperature:0℃~60℃ |
| Pressure Type |
Differential Pressure |
Differential Pressure |
| Overload Capacity |
Allows overload pressure 2 times and destroys pressure 4 times the sensor range |
Allows overload pressure 2 times and destroys pressure 4 times the sensor range |
| Accuracy |
0.5%F.S; 1.0%F.S(optional) |
DP:0.5%F.S 1.0%F.S(optional);Humidity:3%F.S(5%RH~95%RH), TEM:0.5%F.S |
| Long Term Stability |
0.2%F.S/Year |
0.2%F.S/Year |
| Operating Temperature |
0℃~60℃ |
0℃~60℃ |
| Power Supply |
16V~32VDC |
16V~28V DC(Recommend 24V DC) |
| Output Signal |
4mA~20mA DC,RS485+Relay |
4mA~20mA DC,1V ~ 5V DC,RS485(Optional),RS485+Relay |
| Protocol |
MODBUS RTU |
MODBUS RTU |
| Explosion-Proof |
Ex ia IIB T6 Ga |
Ex ia IIB T6 Ga |
| Ambient Temperature |
Stainless Steel |
Stainless Steel |
| Warranty Period |
12 months |
12 months |

4. FRD Sensor FD820CG OEM & ODM Customization Services
FRD Sensor provides professional OEM & ODM customization services for the FD820CG Smart Micro Differential Pressure Transmitter, offering flexible micro differential pressure measurement and system integration solutions based on customers’ specific application requirements.
With high-sensitivity micro differential pressure sensing technology, intelligent temperature compensation algorithms, and precision manufacturing capabilities, FRD Sensor meets the customized needs of cleanroom system integrators, HVAC equipment manufacturers, automation equipment suppliers, and industrial customers.
Customization Options Include:
- Measurement range customization
- Output signal customization
- Display function configuration
- Installation structure optimization
- Communication interface configuration
- Product appearance and branding customization
FRD Sensor provides high-accuracy and high-stability smart micro differential pressure measurement solutions for various applications.
Application-Specific Customization
The FD820CG supports customized solutions for different micro differential pressure monitoring applications, including:
- Cleanroom differential pressure monitoring
- HVAC system pressure control
- FFU (Fan Filter Unit) monitoring
- Air filter differential pressure detection
- Laboratory ventilation systems
- Medical isolation environment monitoring
- Industrial equipment airflow monitoring
System Integration Customization
The FD820CG supports multiple output options to meet different automation and monitoring requirements:
- 4–20 mA output
- Voltage output
- RS485 communication (optional)
Compatible with:
- PLC control systems
- HVAC control systems
- Building Management Systems (BMS)
- Environmental monitoring platforms
Enabling real-time data acquisition, remote monitoring, and intelligent environmental management.
Structural & Manufacturing Support
Based on different installation environments and customer requirements, FRD Sensor provides:
- Embedded installation structure optimization
- Interface design customization
- Product appearance customization
- Technical documentation support
- Mass production services
Helping customers achieve efficient product integration and large-scale applications.
5. FRD Sensor FD820CG Smart Micro Differential Pressure Transmitter Measurement Accuracy Troubleshooting Guide
When the FRD Sensor FD820CG Smart Micro Differential Pressure Transmitter experiences issues such as measurement deviation, signal fluctuation, zero-point drift, display abnormality, or unstable output, engineers can follow the troubleshooting process below to quickly identify the root cause and complete maintenance.
Power Supply & Configuration Check → Installation & Air Connection Inspection → Zero Point & Temperature Compensation Verification → Sensing Element & Electronic Module Inspection
Stage 1: Check Power Supply and System Configuration Parameters
First, confirm that the transmitter power supply and system configuration are operating normally.
Key inspection items include:
- Supply voltage stability
- Wiring connections
- Output signal configuration
- Communication parameter settings
Power supply issues, incorrect configuration, or wiring problems may cause unstable output, abnormal signals, or measurement errors.
Stage 2: Inspect Installation Conditions and Pressure Connections
Check the installation environment and pressure connection conditions:
- Whether air tubes are blocked or leaking
- Whether pressure ports are correctly connected
- Whether installation position is affected by airflow disturbance
- Whether vibration or environmental interference exists
Improper installation conditions or abnormal air connections are common causes of micro differential pressure measurement errors.
Stage 3: Verify Zero Point and Temperature Compensation Performance
Use standard calibration equipment to check:
- Zero-point output
- Measurement accuracy
- Temperature compensation performance
- Output stability
The FD820CG adopts intelligent temperature compensation technology to reduce the influence of environmental temperature variations on measurement performance and improve long-term stability.
Stage 4: Inspect the Sensing Element and Electronic Module
If the installation conditions and external connections are confirmed to be normal but measurement issues still remain, further inspection is required for:
- Micro differential pressure sensing element condition
- Electronic module stability
- Signal processing circuit performance
- Display and data processing functions
6. Application Scenarios


7. Product Certifications

8.Product Drawing


Product dimensions, specifications and parameters are for reference only. For specific details, please contact us, and we will provide you with professional answers.
9.Packing and Shipping
10. Summary
The FRD Sensor FD820CG Smart Micro Differential Pressure Transmitter is designed for low differential pressure monitoring in clean environments, HVAC systems, and precision equipment applications.
With high-sensitivity sensing technology, intelligent temperature compensation, and convenient monitoring capabilities, the FD820CG accurately detects small pressure changes and improves environmental control stability.
From cleanroom pressure management and airflow control to smart building system integration, the FD820CG provides a reliable and efficient micro differential pressure measurement solution for modern applications.